The 30D12Y、30D12R pilot-operated (after valve)pressure control valve

+
  • 30D12.jpg
  • 5(1785914351971).jpg

The company has obtained certifications such as TS equipment A1 level, CE, API 607, TR-CU, SIL3, etc.

Classification:

30 series self operated control valve

Message

Product Description

Summary
The 30D12Y/30D12R pilot–operated (after valve) pressure control valve is composed of the control valve,pilot and actuator.
It is suitable for controlling differential pressure in the pipes of non–crrosive liquids,gases and steams.when the differential pressure rises,the control valve is closed
The main features are as follows:
1.It has the pressure balancing function with high sensitivity.
2.Low noise, reliable performance, free of maintenance
3.The standard modular design is adopted.
4.High control precision

Technical parameters andperformances

Body

DN

DN15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 200,250mm

PN

PN1.6、4.0MPa

Flange standard

ANSI, JIS, DIN, GB, JB(special standards can be offered according to user requirements)

Body material

Cast iron (HT200, cast steel (ZG230-450), cast stainless steel (ZG1Cr18Ni9Ti, ZG1Cr18Ni12Mo2Ti)

Plug material

Hard seal

Stainless steel (1Cr18Ni9Ti, 1Cr18Ni12Mo2Ti)

Stainless steel embedded with rubber ring

Soft seal

Pressure balancing

Stainless steel bellows (DN15~125), balanced diaphragm (DN150~250)

Actuator

Effective area

250 

Pressure setting range

0.01~0.12 0.08~0.25 0.2~0.5 0.45~1 0.6~2.0

Minimum differential pressure that ensures normal work of thepressure valve

0.08 for DN15~125, 0.1 for DN150~250

Allowable maximum differential pressure between the upper and lower diaphragm chambers

0.4 

Material

Diaphragm cover:galvanized steel sheet;diaphragm:EPDM or FKM with fiber

Control pipeline,connection

Copper pipe or steel pipe φ10X1(mm);ferrule connection:R1/4"

Note:※The pressure setting range corresponding to the effective area does not apply to valves with DN150-250.

Performance

Set value error

±4%

Allowable leakage(under stipulated testing conditions)

Hard seal

4x0.01% valve rated capacity

Soft seal

DN15~50

DN65~125

DN150~250

10 bubbles/min

20 bubbles/min

40 bubbles/min

The 30D12Y、30D12R pilot-operated (after valve)pressure control valve

Structural figure

1

Body

2

Seat

3

Stem

4

Before-valve pressure P1 pipe

5

Balanced bellows

6

Travel indicator

7

Diaphragm

8

Spring

9

Operating pressure Ps pipe

10

After-valve pressure P2 pipe

11

Pilot

12

Pilot plug

13

Spring

14

Bellows

15

Adjusting screw

16

Adjustable needle valve

Allowable working temperature

DN

15~125mm

150~250mm

Seal type

Hard seal

≤150°C

≤140°C

Cooling tank≤200°C

Cooling tank and extension ≤200°C

Cooling tank and heat sink ≤350°C※

Cooling tank and extension ≤300°C※

Soft seal

≤150°C

Note:※It indicates the allowable working temperature is valid only when the medium is steam

Rated flow coefficient, noise measuring coefficient, allowable differential pressure

DN

 

15 

20

25

32 

40 

50 

65 

80

100 

125 

150 

200 

250 

Rated flow coefficient

 

4 

6.3

8

16 

20 

32 

50 

80

125 

160 

280 

320 

450 

Noise measuring coefficient Z value

 

0.6 

0.6 

0.6 

0.55 

0.55 

0.5 

0.5 

0.45 

0.4 

0.35 

0.3 

0.2 

0.2 

Allowable differential pressure(Mpa)

PN16

1.6

1.5

1.2

1.0

PN40

2.0

Working principle

The service medium passes through the pressure control valve along the direction indicated by the arrow, and transfers the before-valve pressure P1 to the pilot through the pressure pipe (4). Through adjustment by the adjusting screw (15) at the setting point, the corresponding operating Ps is generated in the pilot. The operating force Ps acts on the upper diaphragm chamber of the actuator, the set pressure (after-valve pressure) P2 acts on the lower diaphragm chamber and is connected with the feedback signal port of the pilot. When the set pressure P2 rises, the compression of the spring (13) in the pilot increases to make the pilot plug (12) move towards the closing direction (downwards) and Ps decreases. Thus, P2 in the lower diaphragm chamber of the actuator increases and Ps in the upper diaphragm chamber decreases to make the plug of the control valve move towards the closing direction, so as to reduce P2 until it returns to the set value.
When P2 decreases, the acting direction is reverse to the above.
When setting the after-valve (or before-valve) pressure at the site, please set the pressure through the adjusting screw (15) and needle valve (16).

Dimensions and weight of control valve

DN(mm)

15 

20 

25 

32 

40 

50 

65 

80 

100 

125 

150 

200 

250 

L(mm)

130 

150 

160 

180 

200 

230 

290 

310 

350 

400 

480 

600 

730 

B(mm)

212 

212 

238 

238 

240 

240 

275 

275 

380 

380 

326 

354 

404 

Weight (Kg)

6.2

6.7

9.7

13

14

17

29

33

60

70

80

140

220

B1(mm)

--

--

--

--

--

--

--

--

--

--

630 

855 

1205 

Weight (Kg)

--

--

--

--

--

--

--

--

--

--

140 

210 

300 

Dimensions and weight of actuator

Effective area(cm²)

250 

R (mm)

263 

H (mm)

DN15~125

150

DN150~250

440

Weight(Kg)

18

22

Keyword:

30 series self operated control valve

pressure

diaphragm

certification

API607 1
API607 2
API607 3
API607 4
API607 5
API607 6

WORKSHOP

Blank size

Blank size

Blank size 1

Blank size 1

Spectral analysis

Spectral analysis

Spectral analysis 1

Spectral analysis 1

Related Products

70S Series low load butterfly valve

The company has obtained certifications such as TS equipment A1 level, CE, API 607, TR-CU, SIL3, etc.

50V Series V ball valve

The company has obtained certifications such as TS equipment A1 level, CE, API 607, TR-CU, SIL3, etc.

50P Series eccentric rotary valve

The company has obtained certifications such as TS equipment A1 level, CE, API 607, TR-CU, SIL3, etc.

70E Series high-performance Butterfly Valve

The company has obtained certifications such as TS equipment A1 level, CE, API 607, TR-CU, SIL3, etc.

Message

*Leave your contact information to get a free product quote