Product Description

Summary     
The 30W02 nitrogen sealing device is composed of the control valve, actuator, pressure spring, pilot, pulse pipe and other parts.   
It is mainly used for maintaining the pressure of gas (generally nitrogen) at the top of the vessel constant so as to prevent the materials in the vessel from contacting the air, volatizing and being oxidized and ensure vessel safety.   
It is especially suitable for gas sealing protection systems of various large‑sized storage tanks. The product has such features as energy saving, agile action, reliable running, convenient operation and maintenance, etc. It is widely used in petroleum, chemical industry, etc.

Technical parameters andperformances

Body

DN

DN20、25、32、40、50、65、80、100mm

PN

PN1.6, 4.0, 6.4MPa

Flange standard

JB/T79.1-94、79.2-94

Body material

Cast iron (HT200, cast steel (ZG230-450), cast stainless steel (ZG1Cr18Ni9Ti, ZG1Cr18Ni12Mo2Ti)

Plug type

Single-seat (P), double-seat (N), sleeve (M)

Plug material

Hard seal

Soft seal

Stainless steel (1Cr18Ni9Ti, 1Cr18Ni12Mo2Ti)

Stainless steel embedded with rubber ring

Stem material

Stainless steel (1Cr18Ni9Ti, 1Cr18Ni12Mo2Ti)

Pressure balancing

Stainless steel bellows

Flow characteristic

Quick open

Working temperature

≤80°C

Actuator

Pressure setting range

0.4~0.5 5~10 9~14 13~19 18~ 24 22~28 27~33 36~44 42~51 49~58 56~66

Diaphragm cover material

Teflon coated A3, A4 steel sheet

Diaphragm material

NBR, EPR, fluorine rubber, oil resistant rubber

1. Main valve2. Main valve plug3. Main valve actuator
4. Pressure reducing valve5. Throttle valve6. Pilot plug
7. Detection mechanism8. Preset spring 

1.Main valve

2.Detection mechanism

3.Spring

Performance

Set value error

±5°C

Allowable leakage

Standard type

Class IV (conforming to GB/T4312-92)

Tight type

Class VI (conforming to GB/T4312-92)

Rated flow coefficient, rated travel, performance

30W02-01 nitrogen supply device

DN

25

32

40

50

65

80

100

Seat size

5

5

7

8

10

12

15

20

25

32

40

50

65

80

100

Flowcoefficient

0.2

0.32

0.5

0.8

1.8

2.8

4.4

6.9

11

20

30

48

75

120

190

Rated travel

8

10

14

20

25

30W02-02 nitrogen discharge device

DN

20

25

32

40

50

65

80

100

Seat size

20

25

32

40

50

65

80

100

Flowcoefficient

6.9

11

20

30

48

75

120

190

Rated travel

8

10

14

20

25

Working principle

In the nitrogen supply device (see figure 1), the medium at the pressure point at the top of the tank is introduced to the detection mechanism (7) through the pressure pipe. The medium produces an acting force on the detection element, which balances the pre‑tightening force of the preset spring (8). When the pressure in the tank drops to be lower than the pressure set point of the nitrogen supply device, the balance is destroyed, so that the pilot plug (6) is opened, and the before‑valve gas enters the upper and lower diaphragm chambers of the main valve actuator (3) after passing through the pressure reducing valve (4) and throttle valve (5). The main valve plug (2) is opened and nitrogen is filled into the tank. When the pressure in the tank rises to the pressure set point of the nitrogen supply device, the pilot plug (6) is closed by the preset spring force. Due to the spring action in the main valve actuator, the main valve is closed and nitrogen supply is stopped.   
The nitrogen discharge device (see figure 2) is an internal feedback mechanism. The medium enters the detection mechanism (2) after passing through the bonnet. The medium produces an acting force on the detection element, which balances the pre‑tightening force of the spring (3). When the pressure in the tank rises to be higher than the pressure set point of the nitrogen discharge device, the balance is destroyed, so that the plug (1) moves upward to open the valve and discharge nitrogen to the outside. When the pressure in the tank falls to the pressure set point of the nitrogen discharge device, the valve is closed by the preset spring force.

1. Outline dimensions and weight of nitrogen supply device

DN(mm)

25

32

40

50 

65 

80 

100 

L

160

180

200

230 

290 

310 

350 

A

308

308

308

308 

394 

394 

394 

H2

415

415

415

115 

415 

415 

415 

H1

60

75

80

85 

95 

105 

120 

H

720

730

730

750 

790 

840 

890 

Weight(kg)

32

35

40

50 

90 

115 

280 

1. Outline dimensions and weight of nitrogen supply device

DN(mm)

25

32

40

50 

65 

80 

100 

L

160

180

200

230 

290 

310 

350 

A

308

308

308

308 

394 

394 

394 

H1

60

75

80

85 

95 

105 

120 

H

380

400

420

430

550

560

570

Weight(kg)

12

13

15

17

20

28

38

Keyword:

30 series self operated control valve

nitrogen

pressure

certification

API607 1
API607 2
API607 3
API607 4
API607 5
API607 6

WORKSHOP

Blank size

Blank size

Blank size 1

Blank size 1

Spectral analysis

Spectral analysis

Spectral analysis 1

Spectral analysis 1

Related Products

70S Series low load butterfly valve

The company has obtained certifications such as TS equipment A1 level, CE, API 607, TR-CU, SIL3, etc.

50V Series V ball valve

The company has obtained certifications such as TS equipment A1 level, CE, API 607, TR-CU, SIL3, etc.

50P Series eccentric rotary valve

The company has obtained certifications such as TS equipment A1 level, CE, API 607, TR-CU, SIL3, etc.

70E Series high-performance Butterfly Valve

The company has obtained certifications such as TS equipment A1 level, CE, API 607, TR-CU, SIL3, etc.

Message

*Leave your contact information to get a free product quote