30D01Y、30D01R self-operated (after-valve)pressure control valve
The company has obtained certifications such as TS equipment A1 level, CE, API 607, TR-CU, SIL3, etc.
Classification:
30 series self operated control valve
E-mail: sunny@reowocv.com
Product Description
The Self Acting Pressure Control Valve is designed for industrial fluid systems that require reliable and automatic pressure regulation. Without relying on complicated external control systems, this valve can respond to changes in process pressure and help maintain a more stable operating condition. Its self-operated structure makes it suitable for applications where continuous pressure control, simple operation, and dependable performance are important.
For industrial users, stable pressure management can help reduce process fluctuations, protect connected equipment, and improve overall system efficiency. The valve can be considered for different pressure-control applications in industrial pipelines and process systems. Its practical design supports easier installation, operation, and maintenance, making it a useful choice for users looking for an efficient pressure-control solution.
Summary
The V230D01/V231D01 self-operated (after-valve) pressure control valve is composed of the control valve, actuator and a spring used for pressure setting. It is suitable for controlling after-valve pressure in the pipes of non-corrosive liquids, gases and steams. When the after-valve pressure rises, the control valve is closed.
The main features are as follows:
1.It has the pressure balancing function with high sensitivity.
2.Low noise, reliable performance, free of maintenance
3.The standard modular design is adopted.
4.Various combined controls can be carried out through the assemblies.
Technical parameters andperformances
| Body | ||
DN | DN15、20、25、32、40、50、65、80、100、125、200、250mm | |
PN | PN1.6、4.0MPa | |
Flange standard | ANSI、JIS、DIN、GB、JB(special standards can be offered according to user requirements) | |
Body material | Cast iron(HT200),cast steel (ZG230-450),cast stainless steel (ZG1Cr18Ni9Ti,ZG1Cr18Ni12Mo2Ti) | |
Plug material | Hard seal | Stainless steel (1Cr18Ni9Ti,1Cr18Ni12Mo2Ti) |
Soft seal | ||
Pressure balancing | Stainless steel bellows(DN15~125),balanced diaphragm(DN150~250) | |
Actuator
Effective area | 32※ | 80 | 250 | 630 |
Pressure setting range | 0.8~1.6 | 0.1~0.6 | 0.015~0.15 | 0.005~0.035 |
Minimum differential pressure that ensures normal work of thepressure valve | ≥0.05 | ≥0.04 | ≥0.01 | ≥0.005 |
Allowable maximum differential pressure between the upper and lower diaphragm chambers | 2.0 | 1.25 | 0.4 | 0.15 |
Material | Diaphragm cover:galvanized steel sheet;diaphragm:EPDM or FKM with fiber | |||
Control pipeline,connection | Copper pipe or steel pipe φ10X1(mm);ferrule connection:R1/4" | |||
Note:※The pressure setting range corresponding to the effective area does not apply to valves with DN150-250.
Performance
Set value error | ±8% | |||
Allowable leakage(under stipulated testing conditions) | Hard seal | 4x0.01% valve rated capacity | ||
Soft seal | DN15~50 | DN65~125 | DN150~250 | |
10 bubbles/min | 20 bubbles/min | 40 bubbles/min | ||
30D01Y、30D01R self-operated (after-valve)pressure control valve

Structural figure
1 | Body | 2 | Seat | 3 | Valve shaft | 4 | Bonnet | 5 | Diaphragm | 6 | Diaphragm |
7 | Spring | 8 | Adjusting | 9 | Pressure | 10 | Bellows | 11 | Balanced | 12 | Charging valve |
Allowable working temperature
DN | 15~125mm | 150~250mm | |
Seal type | Hard seal | ≤150°C | ≤140°C |
Cooling tank≤200°C | Cooling tank and extension ≤200°C | ||
Cooling tank and heat sink ≤350°C※ | Cooling tank and extension ≤300°C※ | ||
Soft seal | ≤150°C | ||
Note:※It indicates the allowable working temperature is valid only when the medium is steam and the bodywith PN40 shall be adopted when the temperature resistance is 350°C.
Rated flow coefficient, noise measuring coefficient, allowable differential pressure
DN |
| 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 |
Rated flow coefficient |
| 4 | 6.3 | 8 | 16 | 20 | 32 | 50 | 80 | 125 | 160 | 280 | 320 | 450 |
Noise measuring coefficient Z value |
| 0.6 | 0.6 | 0.6 | 0.55 | 0.55 | 0.5 | 0.5 | 0.45 | 0.4 | 0.35 | 0.3 | 0.2 | 0.2 |
Allowable differential pressure(Mpa) | PN16 | 1.6 | 1.5 | 1.2 | 1.0 | |||||||||
PN40 | 2.0 | |||||||||||||
Working principle
After throttling by the plug and seat, the before–valve pressure P1 of the process medium is changed into the after–valve pressure P2. Through the control pipeline, P2 is input to the lower diaphragm chamber of the actuator and acts on the top disc. The acting force produced balances the reacting force of the spring, determining relative positions of the plug and seat and controlling the after–valve pressure. When the after–valve pressure P2 increases, the acting force of P2 that acts on the top disc will increase accordingly. At the time, the acting force on the top disc is higher than the reacting force of the spring to make the plug close towards the seat, until the acting force on the top disc balances the reacting force of the spring. At the time, the flow area between the plug and seat is reduced, the flow resistance becomes higher and P2 is reduced to the set value. Likewise, when the after–valve pressure P2 decreases, the acting direction is reverse to the above. This is the working principle during the control of after–valve pressure.
When it is necessary to change the set value of after–valve pressure P2, please adjust the adjusting nut.

Dimensions and weight of control valve
DN(mm) | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 |
L(mm) | 130 | 150 | 160 | 180 | 200 | 230 | 290 | 310 | 350 | 400 | 480 | 600 | 730 |
B(mm) | 212 | 212 | 238 | 238 | 240 | 240 | 275 | 275 | 380 | 380 | 326 | 354 | 404 |
Weight(Kg) | 6.2 | 6.7 | 9.7 | 13 | 14 | 17 | 29 | 33 | 60 | 70 | 80 | 140 | 220 |
B1(mm) | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | 630 | 855 | 1205 |
Weight (Kg) | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | 140 | 210 | 300 |

Dimensions and weight of actuator
Effective area(cm²) | 32 | 80 | 250 | 630 |
R (mm) | 172 | 172 | 263 | 380 |
H (mm) | 435 | 430 | 470 | 520 |
Weight(Kg) | 7.5 | 7.5 | 13 | 28 |
Keyword:
30 series self operated control valve
pressure
diaphragm
quality Self Acting Pressure Control Valve oem
certification
WORKSHOP
Blank size
Blank size 1
Spectral analysis
Spectral analysis 1
Related Products
70S Series low load butterfly valve
The company has obtained certifications such as TS equipment A1 level, CE, API 607, TR-CU, SIL3, etc.
The company has obtained certifications such as TS equipment A1 level, CE, API 607, TR-CU, SIL3, etc.
50P Series eccentric rotary valve
The company has obtained certifications such as TS equipment A1 level, CE, API 607, TR-CU, SIL3, etc.
70E Series high-performance Butterfly Valve
The company has obtained certifications such as TS equipment A1 level, CE, API 607, TR-CU, SIL3, etc.
Message
*Leave your contact information to get a free product quote